How Many ADA Parking Spaces Are Required?
  • November 09, 2026

Introduction

Every parking lot owner eventually wonders how many accessible spaces the law requires them to provide. The answer depends on lot size, and the rules are simpler than most people expect. This guide explains ADA parking requirements for Georgia property owners, from space counts to design details.

For 2026, the federal rules still follow the 2010 ADA Standards for Accessible Design, with no newer replacement in place. We will cover the space counts first and then move on to design rules and special cases.

ADA Parking Requirements in Georgia

Federal and State Rules

The 2010 ADA Standards set the minimum for most public and commercial properties across the country. Georgia adopts those same standards through its state Accessibility Code, which includes the federal sections covering parking and loading zones.

How Local Cities Apply the Rules

Marietta, Alpharetta, Roswell, Woodstock and Acworth all rely on the same federal count rather than separate local formulas. Here is what reviewers in each area typically look at.

  • Marietta checks the space dimensions and the van accessible count in its site development review checklist.

  • Roswell asks for parking calculations and space dimensions on every land disturbance and site plan submission.

  • Acworth checks access aisles, curb cuts, ramps and the 2% slope limit during its development review.

  • Alpharetta and Woodstock apply the federal and state baseline while reviewing development and permit applications.

A city may also add zoning or fire lane rules, but those never reduce the federal minimum count.

How Many Accessible Spaces Does Your Lot Need?

Calculate accessible spaces separately for each parking lot or garage, using the total spaces in that one facility.

The Standard Count Table

Total spaces in one facility Accessible spaces Van accessible spaces
1 to 25 1 1
26 to 50 2 1
51 to 75 3 1
76 to 100 4 1
101 to 150 5 1
151 to 200 6 1
201 to 300 7 2
301 to 400 8 2
401 to 500 9 2
501 to 1,000 2% of total spaces 1 of every 6 accessible spaces
1,001 and over 20 plus 1 per 100 over 1,000 1 of every 6 accessible spaces

Examples

  • A 40 space retail lot needs 2 accessible spaces, and 1 of them must be van accessible.

  • A 600 space garage needs 12 accessible spaces, and at least 2 of them must be van accessible.

Van Accessible Space Rules

How Many Van Spaces You Need

At least 1 of every 6 accessible spaces, or fraction thereof, must be van accessible. A small lot with only one accessible space must make that single space van accessible.

Van Space Layout Options

Van spaces can be 132 inches wide with a 60 inch access aisle or 108 inches wide with a 96 inch aisle. Van accessible spaces also need at least 98 inches of vertical clearance along the aisle and the vehicle route.

Design Rules for Keeping Parking Lots ADA-compliant

Keeping parking lots ADA-compliant means each space must also meet technical standards beyond the simple count.

Core Technical Standards

Feature Requirement
Car space width At least 96 inches
Access aisle width At least 60 inches
Surface Firm, stable and slip resistant
Slope No steeper than 1:48 in any direction
Signage International Symbol of Accessibility, at least 60 inches above the ground
Van clearance At least 98 inches

Why Small Details Matter

A slope of 1:48 equals about 2%, so small paving errors can lead to a failed inspection. Access aisles must also be marked clearly so drivers know not to park inside them.

Location and Accessible Route Basics

Accessible spaces belong on the shortest accessible route to the accessible entrance of the building. When a lot serves several entrances, spread the accessible spaces among them instead of grouping them at one end. The route itself must include compliant curb ramps, level transitions, usable walkway width and proper crosswalks.

ADA Parallel Parking Requirements

Where the Access Aisle Goes

Parallel spaces follow the same count rules as other space types in the same facility. The main difference is where the access aisle sits, which is usually at the end of the space.

Keeping the Route Safe

The aisle must connect to an accessible route and should not force users into moving traffic. Understanding ADA parallel parking requirements helps you avoid costly changes after the layout is approved.

Special Situations That Change the Count

Multiple Lots on One Property

Calculate the requirement for each parking facility on its own instead of adding all spaces together. A property with a 60 space lot and a 140 space lot needs 3 accessible spaces in the first and 5 in the second. Counting all 200 spaces together would give only 6, which falls short of the 8 required.

Medical Facilities

Outpatient facilities must make at least 10% of all patient and visitor parking spaces accessible under the ADA. Facilities that specialize in treating mobility impairments must reach 20%, which is far above the standard table.

Residential and Valet Properties

Residential projects such as apartments and assisted living follow different rules tied to unit counts and housing type. If a property offers valet service, an accessible passenger loading zone is generally required as well.

Restriping and Repairs

When a lot is restriped, repaired or resurfaced, the requirement is recalculated for that entire facility.

Common Mistakes With ADA Parking Requirements

These mistakes are common in the field and often lead to failed inspections and expensive rework.

  • Counting the whole shopping center instead of each separate lot or garage.

  • Providing enough accessible spaces but too few van accessible spaces.

  • Making the access aisle too narrow or letting vehicles park inside it.

  • Placing accessible spaces far from the entrance or along a noncompliant route.

  • Losing the 98 inch vertical clearance for van spaces, especially in parking decks.

  • Assuming local zoning minimums replace the federal rules when they usually work alongside them.

Additional Considerations

  • Confirm the approved site plan with your local building or community development department before any striping begins.

  • Measure the finished slope after paving because small grading errors can push a space past the 1:48 limit.

  • Check overhead clearance in parking decks before you place any van accessible space near beams or pipes.

  • Keep a copy of the approved plan on file for future inspections and restriping jobs.

Final Words

Getting the count and the design right protects your visitors and also protects your property from costly rework. ADA compliant parking requirements are simple to follow once you calculate each lot separately and plan the layout details early.

New Pointe Contracting is an asphalt paving and concrete contractor serving residential and commercial customers across North Georgia. We provide asphalt paving, sealcoating, asphalt repairs, resurfacing, crack sealing, concrete installation and parking lot maintenance. With 40 years of experience and more than 3,000 completed projects, we serve Marietta, Alpharetta, Roswell, Woodstock and Acworth. Call us at 404-414-7192 for enquiries and paving project estimates.

FAQs

For 2026, the federal design rules are still the 2010 ADA Standards for Accessible Design. No newer set has replaced them. New construction and alterations must follow them, and existing facilities must still remove barriers where readily achievable.

It depends on the total spaces in one lot or garage. A lot with 1 to 25 spaces needs 1, and a lot with 51 to 75 spaces needs 3. Larger lots follow the count table above.

Ramps generally need a running slope no steeper than 1:12 and a cross slope no steeper than 1:48. They also need 36 inches of clear width, level landings at both ends and handrails when the rise exceeds 6 inches.

At least 1 of every 6 accessible spaces, or fraction thereof, must be van accessible. Every facility with accessible parking needs at least one van space, so a lot with 7 accessible spaces needs at least 2.

A standard accessible car space must be at least 96 inches wide, which is 8 feet. It also needs an adjacent access aisle at least 60 inches wide, marked so that drivers do not park there.

An accessible space and its access aisle cannot be steeper than 1:48 in any direction. That equals about 2%, so a surface that looks flat can still fail if the grading is slightly off.

Yes, it often does. When a lot is restriped, repaired, resurfaced or altered, the requirement is recalculated for that facility, so you may need to provide the current number and design of accessible spaces.

Each accessible space needs a sign showing the International Symbol of Accessibility. The bottom of the sign must be mounted at least 60 inches above the ground. Georgia may also add its own signage rules.

No. Each parking lot or garage is calculated on its own. A 60 space lot and a 140 space lot need 3 and 5 accessible spaces, which is more than a combined count would suggest.

They should sit on the shortest accessible route to the accessible entrance. When a lot serves several entrances, spread the spaces among them and make sure the route has compliant curb ramps and crosswalks.

Recent Posts
Need a custom quote

Contact for your parking lot and asphalt needs

Contact Our Team

Or Have A Question? Call Us

404-414-7192